Gas Meter Sizing Tool

Gas Conversion and Sizing for Turbine Meters

Sizing a meter for gas requires a conversion of units to Actual Cubic Feet per Minute (ACFM). This can be easily done by following a three-step process. 

Please Note: All calculations are at sea level.

  • Step 1:  Enter number of units and type of units to perform conversion to Standard Cubic Feet per Minute (SCFM).

Quantity

Units

SCFM

     
     
     
  • Step 2:  Enter the derived SCFM units value along with your PSIG value and your temperature in °F as directed. This will calculate your ACFM units:

SCFM =

 
     

PSIG * = 

 
     

degrees F = 

 
     
     

 ACFM =

 

Automatic recalculation (changes calculations as variables change)

*Automatically adds 14.696 

  • Step 3:  Choose the proper sizing from the chart provided based on ACFM.

NORMAL FLOW RANGE (ACFM)
(MAGNETIC PICKUP)
METER SIZE MINIMUM
LINEAR
MAXIMUM
LINEAR
1/4 0.35 3.5
3/8 0.75 5
1/2 1 10
5/8 2 20
3/4 2.5 28
1 4 60
1 1/4 6 100
1 1/2 8 130
2 15 250
2 1/2 25 450
3 40 650
4 75 1200
5 150 1800
6 250 2900
8 330 5000
10 650 7500
12 900 12000

The browser does not support JavaScript. The calculations created using ExcelEverywhere will not work. Please access the web page using another browser.